ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components

Product Details
Customization: Available
After-sales Service: 24/7 Online Service
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
44
Year of Establishment
2013-09-17
  • ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components
  • ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components
  • ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components
  • ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components
  • ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components
  • ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components
Find Similar Products
  • Overview
  • Product Description
  • Recommend Products
  • Feedback
  • Company Profile
Overview

Basic Info.

Model NO.
VS-9809
Appliance
Biochemistry
Gaspath System
Three
Certification
CE, ISO, IEC
Stationary Phase
Solid Adsorbent
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Convetional Analytical Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
20~40mm
Product Name
Oil Gas Chromatograph
Voltage Range
0.5~10kv
Test Current Range
10μa~1A
Power Factor
0.02 < Cos φ < 0.1
Current Range
0.5A ~ 15A (Internal), 0.5A ~ 50A (External)
Frequency Measuremen
45 ~ 65Hz
Ambient Temperature
-10°c to 50°c
Ambient Humidity
≤85℅rh, Non-Condensing
Operating Power Supply
AC220V ±10%
Transport Package
Poly Crate with Foam
Trademark
Weshine
Origin
Baoding, China
HS Code
9030332000
Production Capacity
500PCS/Month

Product Description

Product Description

     
When the highest levels of throughput are critical to your operations, choose the VS-9809GAS CHROMATOGRAPH. Its patented high-performance oven delivers the fastest heat-up and cool-down of any oven in the business, and that means shorter injection-to-injection times, and the ability to run more samples per day. Plus, the oven's twin-wall design with concentric air exhaust provides exceptional cooling to near-ambient temperatures without resorting to liquid cryogen - critical for analysis of VOCs. Weshine invented that VS-9809 has a wide-range flame ionization detector (FID), a new high-performance capillary injector with decreased reactivity, and autosampler technology that delivers multiple options for liquid injection, headspace, and SPME on one system.
 
Weshine VS-9809 GAS CHROMATOGRAPH specializes in the analysis of gases in transformer insulating oil. The Gas Chromatograph can analyze 7/9/11 kinds of gas components in the insulating oil through two or three chromatographic columns.

Gas Chromatograph works with the Air Generator, Hydrogen Generator, and Oscillator.

The Oscillator shocks and heats up the oil sample to get the gas from the oil. And then inject the gas sample into the Gas Chromatograph. Before that, we should use the Air Generator and Hydrogen Generator to fire the FID1 and FID2.The Gas Chromatograph will analysis the gas sample automatically, and you will see the gases components waves on the software on PC.

The test report can be printed by the printer from the Gas Chromatograph.

If there are many oil samples needed to be tested, then the Headspace Autosampler can help. 27 Samples can be shocked and heated, and then transmit the gas samples automatically by the Autosampler. It can help the Gas Chromatograph a lot, and save labor cost and time cost.
ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components
ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 ComponentsASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components
PRODUCT INFORMATION
Product Name
GAS CHROMATOGRAPH
Operation Display
5.7 inch lattice localization color LCD
Control Region
6 pc

Temperature Range
Column oven temperature: +5 ~ 420 ºC , Accuracy: ± 0.1 ºC
Detection room temperature: +5 ~ 420 ºC , Accuracy: ± 0.1 ºC
Conversion furnace temperature: +5 ~ 420 ºC , Accuracy: ± 0.1 ºC
External Event
4 channels
Type of Detector
FID, TCD, ECD, FPD
Standards
ASTM D2887,D7169,D6352 ...
Certificates
CE; EMC; LVD; ISO; IEC;
Dimensions
455mm*530mm*220mm
Model Number
VS-9808

ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 ComponentsASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 ComponentsASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 ComponentsASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components

 

Recommend Products

ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components
VS-27 
AUTOMATIC HEADSPACE SAMPLER
* Used for GC Sample Preparation & Introduction
* 10ml and 20ml headspace vials can be used to meet a large number of analytical requirements.
* The start bottle position and end bottle position can be set freely.
* 6 sample heating positions can be overlapped for heating.
* Automatically detect leaked sample vials.
* Vial shaking function accelerates equilibration time and improves efficiency.

 

VS-9808 
GAS CHROMATOGRAPH
 
* The highest levels of throughput.
* Patented high-performance oven.
* The fastest heat-up and cool-down in the business.
* Twin-wall design with concentric air exhaust.
* Wide-range flame ionization detector (FID)
* New high-performance capillary injector.
* Autosampler delivers multiple options for liquid injection, headspace, and SPME on one system.
ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components

Feedback

ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components

Company Profile

 

 

ASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 ComponentsASTM GC Ms Column Quad Natural Gas Chromatography Instrument Price 7 / 9 / 12 Components

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More