Set 60kv AC Low Frenquency Vlf Hipot Tester
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | 24/7 Online Service |
| Warranty: | 1 Year |
Manufacturer/Factory & Trading Company
360° Virtual Tour
Secured Trading Service
Diamond Member Since 2022
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Cooperated with Fortune 500
Years of Export Experience
Exhibition Experience
Management Certification
This supplier has Cooperated with Fortune 500 companies
The export experience of the supplier is more than 10 years
The supplier had participated in offline trade shows, you can check the Audit Report for more information
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
GB/T 27922-2011 standard Five stars grade
ISO9001:2015 certificate
ISO14001
ISO45001:2018 certificate
GB/T 27922-2011 standard Five stars grade
Sign In to see all verified strength labels (26)
Find Similar Products
Basic Info.
- Model NO.
- VS-VLF
- Display Type
- Analogue and Digital
- Certification
- CE
- Customized
- Customized
- Product Name
- Vlf Cable Tester
- Output Frequency
- 0.1Hz, 0.05Hz, 0.02Hz
- Output Voltage
- 30kv/40kv/50kv/60kv/80kv/90kv
- High Test Capacity
- 5.5μf
- Typical Application
- Power Cables Below 35kv; Generators Hipot Test.
- Accuracy
- 3%
- Safety
- Overload Protection
- Power Supply
- AC 220 V ±10%, 50 Hz
- Weight
- 4+25 Kg
- Vlf Cable Tester
- Vlf Hipot High Voltage Test System
- Transport Package
- Wooden Box with Foam Inside
- Specification
- 80kV/1.1μ F: Test 35kV Cables + Generators
- Trademark
- Weshine
- Origin
- China Hebei
- HS Code
- 903033900
- Production Capacity
- 500 Pieces/Per Month
Product Description
VLF testing uses very low frequencies as part of an AC cable maintenance routine. VLF testers are smaller and more practical than AC testers but output the same amount of power as a 50 Hz mains device. This combination of size and power makes Very Low Frequency cable testing perfect for testing longer sections of cable and apparatus.
AC is the standard used to transmit power worldwide, usually at a frequency of 50 or 60 Hertz. While supplies to railways and aircraft may use 162/3 of 400Hz, it is still a sinusoidal voltage waveform. A VLF test is ideal for working within these parameters.
Transmitting power with an alternating current is not as efficient as with a direct current however: while all power transmission lines and cable networks do have the side effect of DC resistance loss to the supply voltage, the level of capacitive loss is even higher. This is largely due to the inherent coupling between the phases involved. As a result, generating systems must supply enough energy to meet user demand as well as compensate for the large losses stemming from the transmission process. The small size and high power of the VLF tester helps to solve the practical problem of transmission loss during an AC test on very long sections of cable and apparatus in the field.
This equipment negates the need for on-site generation, large step down transformers or generating company supplies to be employed to power the items under test.
Because VLF testing supplies a working frequency of 0.1Hz as opposed to the 50/60Hz usually required for live transmission, the physical size of the VLF test set is massively reduced. Critically, the test object still receives the Alternating Sinusoidal Voltage that would be supplied through everyday use, but the size of the test equipment is much smaller.
WESHINE invented the CDP series is a compact, robust and portable VLF sine wave test system for medium voltage cables. As an ideal tool for routine cable testing. For both 0.1 Hz sine wave voltage tests and rectangular or DC voltage tests, the VLF sine wave 34 kV fills the highest demands on the test voltage quality and stability. Moreover, the integrated "breakdown detection" shuts down the test voltage in the event of an excessive charge current and guarantees limited damage to the cable.
AC is the standard used to transmit power worldwide, usually at a frequency of 50 or 60 Hertz. While supplies to railways and aircraft may use 162/3 of 400Hz, it is still a sinusoidal voltage waveform. A VLF test is ideal for working within these parameters.
Transmitting power with an alternating current is not as efficient as with a direct current however: while all power transmission lines and cable networks do have the side effect of DC resistance loss to the supply voltage, the level of capacitive loss is even higher. This is largely due to the inherent coupling between the phases involved. As a result, generating systems must supply enough energy to meet user demand as well as compensate for the large losses stemming from the transmission process. The small size and high power of the VLF tester helps to solve the practical problem of transmission loss during an AC test on very long sections of cable and apparatus in the field.
This equipment negates the need for on-site generation, large step down transformers or generating company supplies to be employed to power the items under test.
Because VLF testing supplies a working frequency of 0.1Hz as opposed to the 50/60Hz usually required for live transmission, the physical size of the VLF test set is massively reduced. Critically, the test object still receives the Alternating Sinusoidal Voltage that would be supplied through everyday use, but the size of the test equipment is much smaller.
WESHINE invented the CDP series is a compact, robust and portable VLF sine wave test system for medium voltage cables. As an ideal tool for routine cable testing. For both 0.1 Hz sine wave voltage tests and rectangular or DC voltage tests, the VLF sine wave 34 kV fills the highest demands on the test voltage quality and stability. Moreover, the integrated "breakdown detection" shuts down the test voltage in the event of an excessive charge current and guarantees limited damage to the cable.
|
PRODUCT INFORMATION
|
|||
|
Product Name
|
VLF Hpot Tester
|
||
|
Model Number
|
VS-VLF
|
Output Frequency
|
0.1 Hz, 0.05 Hz, 0.02 Hz
|
|
Output Voltage
|
30 kV ~ 90 kV
|
High Test Capacity
|
5.5 μF
|
|
Protection Function
|
Over-voltage Protection, Over-current Protection.
|
||
|
Typical Application
|
Power Cables Below 35 kV; Generators Hipot Test.
|
||
|
Certificates
|
CE; EMC; LVD; ISO; IEC;
|
Weight
|
4+25 kg+25kV
|