Weshine Electric Insulated Boots And Gloves Testers

Product Details
Customization: Available
After-sales Service: 7*24 Online Service/Change New
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
44
Year of Establishment
2013-09-17
  • Weshine Electric Insulated Boots And Gloves Testers
  • Weshine Electric Insulated Boots And Gloves Testers
  • Weshine Electric Insulated Boots And Gloves Testers
  • Weshine Electric Insulated Boots And Gloves Testers
  • Weshine Electric Insulated Boots And Gloves Testers
  • Weshine Electric Insulated Boots And Gloves Testers
Find Similar Products

Basic Info.

Model NO.
VS-2910
Display Type
Digital Only
Certification
CE
Customized
Customized
Rated Output Voltage
50kv (Insulation Boots and Gloves Test)
Rated Capacity
5kVA
Output Voltage Range
50.0kv (250V)
Voltage Measurement
Error:<±(1.0 %U+0.1%Umax)
Input Current Process
25.0A
Leakage Current Resolution
0.01 Ma
Leakage Current Measurement
Error:±(0.5%I+2 Words)
Transport Package
Polycrate with Plastic Foam
Trademark
Weshine
Origin
Hebei, China
HS Code
903039
Production Capacity
2000

Product Description

Weshine Electric Insulated Boots And Gloves TestersWeshine Electric Insulated Boots And Gloves TestersWeshine Electric Insulated Boots And Gloves Testers
1. Overview

Insulated boots and gloves are the necessary safety equipment for power system operation and maintenance DL / T1476 Regulations for preventive test of electrical appliances for safety of electric industry the test method and cycle of common safety equipment such as insulating boots and gloves are stipulated.Insulated boots and gloves voltage test, the cycle is half a year, the test process is not allowed to break down, Simultaneously insulated boots leakage current is less than the limit value.
The instrument adopts multi-channel high voltage leakage current measurement patent technology and infrared data communication technology to achieve the safe measurement of high voltage leakage current purposes.Through the application of this technology, the tester is completely isolated from the high-voltage system, which can not only accurately measure the multi-channel high-voltage leakage current, but also ensure the personal safety of tester.
In order to improve work efficiency, 8 samples can be tested at the same time. In order to avoid repeated testing , the high voltage breaking patent technology is adopted. During the process of testing, the breakdown samples can be separated from the High Voltage test system. No breakdown of the test continued until the test is completed.

2. Main functions
   
2.1 Simultaneous testing of 8 insulating boots or gloves to measure leakage current separately.
    2.2 Large screen LCD display with a large amount of information, only one screen simultaneously can  display 8 high-voltage leakage current, test voltage, current, timing time and other parameters.
    2.3 Parameters such as test voltage and primary current of test transformer can be measured.
    2.4 The use of proprietary infrared communication technology ,in order to completely isolate the operating table from the high-voltage system ensure the safety of the tester.
    2.5 Fully automatic pressure test.After the start of the test, the instrument automatically shuts down automatically to the national standard to request the booster speed to raise the voltage automatically,and rises to the predetermined voltage to start the time and maintains the test voltage, the time automatically drops the voltage to zero and the power is cut off. Simultaneously, the leakage current of each sample is displayed and the test results are automatically saved.
    2.6 Has a special earthing container for easy operation.
    2.7 Each sample is equipped with a high-voltage break mechanism, when any one way of breakdown, the road test will be automatically removed from the high pressure, and do will not affect the test.
    2.8 Has the function of overvoltage and overcurrent protection.
    2.9 High pressure hazard warning lamp display.
    2.10 The instrument can save 60 groups of test data and results, which always can be consulted at any time.
    2.11 Real-time calendar clock functionality.
3. Main technical parametersRated output voltage:50kV (Insulation boots and gloves test)
    Rated capacity:5kVA
    Output voltage range:50.0 kV(250V)
    Voltage measurement error:<±(1.0 %U+0.1%Umax),
                 Where U is the indication value and Umax is the upper limit value of the range.
   Input current process:25.0A
   Current measurement error:<±(0.5%I+0.05%Imax),
                Where I is the indication value and Imax is the upper  limit value of the range
   Test position: 8
   Leakage current path:25.0mA
   Leakage current measurement error:±(0.5%I+2 words)
   Leakage current resolution:0.01 mA

Weshine Electric Insulated Boots And Gloves Testers
Weshine Electric Insulated Boots And Gloves TestersWeshine Electric Insulated Boots And Gloves TestersWeshine Electric Insulated Boots And Gloves TestersWeshine Electric Insulated Boots And Gloves Testers
Weshine Electric Insulated Boots And Gloves Testers
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More