Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

Weshine Electric Manufacturing Co., Ltd.
  • Audited Supplier
  • 5 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Images of Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area pictures & photos
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area pictures & photos
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area pictures & photos
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area pictures & photos
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area pictures & photos
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area pictures & photos
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
    Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
    Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
    Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
    Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
    Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
    Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

Find Similar Products

Product Description

 

Product Description

During the operation of power grid companies for many years, due to various technical reasons, non-standard management or power and responsibility adjustment, the end-user meter files do not conform to the actual situation, and it is difficult to determine the location of the ground cable power users. Further, the disordered accounts cause that the analysis of line loss rate, distribution network fault location, emergency repair work list issuance and three-phase imbalance analysis and some other advanced applications cannot be effectively carried out. Seriously affected the process of building smart grid by Power Grid Corp.
 
For this reason, Weshine invented the Transformer Area Identifier which based on the high correlation of voltage data of the same electrical energy acquisition equipment, the voltage data of users are clustered to realize the users in the same transformer area. Examples show that the proposed transformer area recognition method can accurately and effectively identify the user transformer area and phase information and reduce the labor and hardware costs. It is of great significance to guide the operation, maintenance, emergency repair, technical renovation and planning of low-voltage distribution network.
 
PRODUCT INFORMATION
Product Name
Two-way Transformer Area Identifier
Typical Application
Distribution network transformer area survey, transformer area contracting, electricity inspection, production scheduling and operation and maintenance maintenance, etc.
Rated Voltage
3 x 200 V
Rated Frequency
50 Hz
Communication Mode
Low frequency zero crossing communication technology
SIGNIFICANCE 
of 
TRANSFORMER 
AREA 
IDENTIFIER
Compared with products based on FSK carrier communication technology, this product has the characteristics of high signal-to-noise ratio, strong signal and accurate information identification. Compared with similar products, it has the characteristics of fast recognition speed, no common high voltage cross-connection, common cable trench cross-connection, common zero line cross-connection, intuitive display and simple operation.
Communication Distance
> 5km
Identification Accuracy
100 %
Model Number
VS-X705B
Certificates
CE; EMC; LVD; ISO; IEC;


Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
TYPICAL APPLICATION
1. The instrument adopts aluminum alloy portable integrated box design, which has good mechanical properties and anti-corrosion performance. The whole machine is light in weight, and the terminal can be placed in the main box, which is very suitable for on-site carrying and use.
 
2. Both the terminal and the host use a large-screen dot-matrix liquid crystal display, all displayed in Simplified English(Customizable), with intuitive operation and a background light, which is convenient for use in dark places.
 
3. The terminal and the host are flexibly configured, there is no binding relationship, and there is no need to re-set during configuration. The host number can be flexibly changed through the keyboard, so as to realize the user identification of the power supply area of multiple distribution transformers under complex conditions.
 
4. The host has a real power supply anti-misconnection protection function. When the 220V power supply is mistakenly connected to 380V, the instrument will quickly and automatically cut off the circuit to protect the safety of the instrument and the operator.
 
5. The terminal has a countdown prompt function and voice prompt when waiting (after receiving the signal), which is very convenient for users to use.
  

Recommend Products

Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
 
VS-X710
POWER QUALITY ANALYZER
* 0.05 to 6 A(up to 1500 A), 10 to 450 V
* 3 voltage channels/3 current channels
 
MEASURED PARAMETERS:
 
* Power parameters (KW, KVAR, KVA, DPF, TPF)
* Energy parameters (KWH, KVARH, KVAH)
* Voltage/current unbalance
* RMS voltage/current
* Total demand distortion
* Harmonics
* Harmonic ripples
* Total harmonic distortion
* Flicker
* Phase angles
* Phase angle deviation
VS-X710
POWER QUALITY ANALYZER
* 1280*800 Touch LCD screen
* 0 to 25 A(up to 2000 A), 0 to 900 V
* 4 voltage channels/4 current channels
 
MEASURED PARAMETERS:
 
* Power parameters (KW, KVAR, KVA, DPF, TPF)
* Energy parameters (KWH, KVARH, KVAH)
* Voltage/current unbalance
* RMS voltage/current
* Total demand distortion
* Harmonics
* Harmonic ripples
* Total harmonic distortion
* Flicker
* Phase angles
* Phase angle deviation
Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area


 

Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

Feedback

Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

Company Profile

Bidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer AreaBidirectional Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR256884". Items marked "verified" are certified.

Watch Video
Watch Video
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Room 602, Building 3, Diangu Technology Center, 3088 Lekai North Street, Baoding, Hebei, China
verified Plant Area
2695 square meters
verified Number of Employees
53
verified Registered Capital
30,500,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Tianjin Port
verified Minimum Order Quantity
1 Pcs
verified Supply Chain Partners
6

Our Production Capability & Technical Expertise

verified Main Products
Testing Equipment
verified Production Lines
1
verified Production Machines
Assembly Line
verified QA/QC inspectors
1 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Minor Customization, Full Customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
12 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2013-09-17
verified Export Year
12 Years
verified Main Markets
Southeast Asia/ Mideast, Domestic
verified Repeat Buyers Choice
30%~50%
verified Number of Foreign Trading Staff
3
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015, ISO14001, ISO45001:2018, Others
verified Cooperated with Fortune 500
Yes

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs