90kv 60kv withstand test VLF cable testing equipment
90kv 60kv withstand test VLF cable testing equipments are smaller and more practical than AC testers but output the same amount of power as a 50 Hz mains device. This combination of size and power makes Very Low Frequency cable testing perfect for testing longer sections of cable and apparatus.
AC is the standard used to transmit power worldwide, usually at a frequency of 50 or 60 Hertz. While supplies to railways and aircraft may use 162/3 of 400Hz, it is still a sinusoidal voltage waveform. A VLF test is ideal for working within these parameters.
Transmitting power with an alternating current is not as efficient as with a direct current however: while all power transmission lines and cable networks do have the side effect of DC resistance loss to the supply voltage, the level of capacitive loss is even higher. This is largely due to the inherent coupling between the phases involved. As a result, generating systems must supply enough energy to meet user demand as well as compensate for the large losses stemming from the transmission process. The small size and high power of the VLF tester helps to solve the practical problem of transmission loss during an AC test on very long sections of cable and apparatus in the field.
This 90kv 60kv withstand test VLF cable testing equipment negates the need for on-site generation, large step down transformers or generating company supplies to be employed to power the items under test.
Because 90kv 60kv withstand test VLF cable testing equipment testing supplies a working frequency of 0.1Hz as opposed to the 50/60Hz usually required for live transmission, the physical size of the VLF test set is massively reduced. Critically, the test object still receives the Alternating Sinusoidal Voltage that would be supplied through everyday use, but the size of the test equipment is much smaller.
WESHINE invented the CDP series withstand test VLF cable testing equipment is a compact, robust and portable VLF sine wave test system for medium voltage cables. As an ideal tool for routine cable testing. For both 0.1 Hz sine wave voltage tests and rectangular or DC voltage tests, the VLF sine wave 34 kV fills the highest demands on the test voltage quality and stability. Moreover, the integrated "breakdown detection" shuts down the test voltage in the event of an excessive charge current and guarantees limited damage to the cable.
VLF testing uses very low frequencies as part of an AC cable maintenance routine.
|
|
90kv 60kv withstand test VLF cable testing equipment |
|
|
|
0.1 Hz, 0.05 Hz, 0.02 Hz
|
|
30 kV ~ 90 kV
|
|
5.5 μF
|
|
Over-voltage Protection, Over-current Protection.
|
|
Power Cables Below 35 kV; Generators Hipot Test.
|
|
CE; EMC; LVD; ISO; IEC;
|
|
4+25 kg
|