Basic Info.
- Model NO.
- VS-FZX
- Product name
- LOAD TEST CABINET
- Power factor
- R+L is adjustable from 0.2 to 0.998;
- Power
- 10KVA or 3X10KVA.
- Capacity
- 70uf 140uf 73uf.
- Output current
- R and R+L two ways, the range is 0.1-40.0A,
- Input power
- AC220 / 380 V±10%, 50/60 Hz
- Output voltage
- manual voltage regulation range AC0-300V continuou
- Cooling method
- fan forced cooling
- Leakage protection
- yes
- Overload protection
- yes
- Transport Package
- Wooden Case
- Specification
- VS-FZX: POWER RESISTANCE LOAD TEST CABINET
- Trademark
- Weshine
- Origin
- Hbei, China
- HS Code
- 9030849000
- Production Capacity
- 2000 Pieces Per Month
Packaging & Delivery
- Package Size
- 60.00cm * 60.00cm * 150.00cm
- Package Gross Weight
- 90.000kg
Product Description
Weshine invented Power Resistance Load Test Cabinet is suitable for testing the analog load of switches, plugs and sockets, connectors, wires and cables, household appliances and other occasions. The ideal load test equipment for institutions.

|
Product name
|
POWER RESISTANCE LOAD TEST CABINET
|
||
|
Power factor
|
R+L is adjustable from 0.2 to 0.998;
|
||
|
Output current
|
R and R+L two ways, the range is 0.1-40.0A,
|
||
|
Input power
|
AC220V±10%, 50/60Hz, or AC380V±10%, 50/60Hz
|
||
|
Output voltage
|
manual voltage regulation range AC 0 to 300 V continuously adjustable;
|
||
|
Cooling method
|
fan forced cooling
|
||
|
Leakage protection
|
yes
|
Overload protection
|
yes
|
|
Capacity
|
70uf 140uf 73uf.
|
Power
|
10KVA or 3X10KVA.
|





1. Automatically measure the wiring group.
2. Automatic group conversion, which can directly measure the transformation ratio of single-phase, three-phase transformers and transformers.
3. Automatically switch the phase sequence.
4. Automatically switch the range.
5, automatic calibration table.
6. After inputting the standard transformation ratio, the relative error can be automatically calculated.
7. After one measurement is completed, the test voltage is automatically cut off.
8. The measurement results are automatically saved, the test data can be printed out, and 20 historical measurement data can be stored.