After-sales Service: 24/7. All Time Zones Friendly
Warranty: 1 Year
Product Name: Lightning Impulse Voltage Generator
Ray waves: ≥85%
Operating wave: ≥80%
Nominal voltage: 300 kV to 4800 kV
Samples:
US$ 39999/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Feedback
  • Company Profile
Overview

Basic Info.

Model NO.
VSJC-Y1200
Rated voltage
± 150kV to 1200 kV
Rated capacitance
0.325 to 1.0 μF
Impact energy
7.31 to 480 kJ
Transport Package
Wooden Box with Foam Inside
Specification
VSJC-Y400: Lightning Impulse Voltage Generator
Trademark
Weshine
Origin
China Hebei
HS Code
8504210000
Production Capacity
300 Pieces/Per Month

Product Description

Product Description

Lighting is a common phenomenon in transmission lines because of their tall height. This lightning stroke on the line conductor causes impulse voltage. The terminal equipment of transmission line such as power transformer then experiences this lightning impulse voltages. Again during all kind of online switching operation in the system, there will be switching impulses occur in the network. The magnitude of the switching impulses may be about 3.5 times the system voltage. Insulation is one of the most important constituents of a transformer. Any weakness in the insulation may cause failure of transformer. To ensure the effectiveness of the insulation system of a transformer, it must confirms the dielectric test. But the power frequency withstand test alone can not be adequate to demonstrate the dielectric strength of a transformer. That is why impulse test of transformer performed on it. Both lightning impulse test and switching impulse test are included in this category of testing.

 
From the data compiled about natural lightning, it may be concluded that the system disturbance due to natural lightning stroke, can be represented by three basic wave shapes.
 
* Full wave
* Chopped wave and
* Front of wave
 
Although the actual lightning impulse disturbance may not have exactly these three shapes but by defining these waves one can
establish a minimum impulse dielectric strength of a transformer.

If lighting disturbance travels some distance along the transmission line before it reaches the transformer, its wave shape may approach to full wave. If during traveling, if flash-over occurs at any insulator of the transmission line, after the peak of the wave has been reached, the wave may become in form of chopped wave.
 
If the lightning stroke directly hits the transformer terminals, the impulse voltage rises rapidly until it is relieved by a flash over. At the instant of flash-over the voltage suddenly collapses and may form the front of wave shape.

The effect of these waveforms on the transformer insulation may be different from each other. We are not going here in detail discussion of what type of impulse voltage waveforms causes what type of failure in the transformer. But whatever may be the shape of lightning disturbance voltage wave, all of them can cause insulation failure in the transformer. So lighting impulse test of transformer is one of the most important type test of transformer.
For regulatory requirements and operator safety, it is necessary to know the levels of insulation in the transformers. Weshine has 8 years experience specifically for deal with complete range of Lightning Impulse Test Equipment.

For further information on Weshine's Service Solutions, contact our 24/7 online sales representative.
Product Name
Lightning Impulse Voltage Generator
Model Number
VSJC-Y400
Nominal Voltage
300 to 4800 kV
Rated Voltage
± 150  ~ 1200 kV
Rated Capacitance
0.325 to 1.0 μF
Impact Energy
7.31 to 480 kJ
Ray Waves
≥85%
Operating Wave
≥80%
Typical Application
Testing of:
Power transformer, Cable, Arrester(impact current test), Generator, Motor, Insulator, Casing, GIS, Transformer, Capacitor, Other insulating materials, Scientific research and teaching

3 Waveforms 400kV 800kV 1200kV Withstand Voltage Generator HV Lightning Impulse Voltage Test Device3 Waveforms 400kV 800kV 1200kV Withstand Voltage Generator HV Lightning Impulse Voltage Test Device3 Waveforms 400kV 800kV 1200kV Withstand Voltage Generator HV Lightning Impulse Voltage Test Device3 Waveforms 400kV 800kV 1200kV Withstand Voltage Generator HV Lightning Impulse Voltage Test Device
Feedback
3 Waveforms 400kV 800kV 1200kV Withstand Voltage Generator HV Lightning Impulse Voltage Test Device

 

Company Profile

3 Waveforms 400kV 800kV 1200kV Withstand Voltage Generator HV Lightning Impulse Voltage Test Device3 Waveforms 400kV 800kV 1200kV Withstand Voltage Generator HV Lightning Impulse Voltage Test Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now