Frenquency CT PT Tester Transformer Characteristic Parameters Analyzer

Product Details
Customization: Available
After-sales Service: 24/7 Online Service
Warranty: 1 Year
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
44
Year of Establishment
2013-09-17
  • Frenquency CT PT Tester Transformer Characteristic Parameters Analyzer
  • Frenquency CT PT Tester Transformer Characteristic Parameters Analyzer
  • Frenquency CT PT Tester Transformer Characteristic Parameters Analyzer
  • Frenquency CT PT Tester Transformer Characteristic Parameters Analyzer
  • Frenquency CT PT Tester Transformer Characteristic Parameters Analyzer
  • Frenquency CT PT Tester Transformer Characteristic Parameters Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Recommend Products
  • Feedback
  • Company Profile
Overview

Basic Info.

Model NO.
VS-2800A
Display Type
Digital Only
Certification
CE
Customized
Customized
Product Name
PT and CT Analyzer (Variable Frequency)
Power Supply
AC220 V±10% ,50 Hz
Device Output
0 ~ 220 Vrms, 5 Arms (20 a Peak)
Current Output
0 ~ 150 a
CT Ratio Measurement Range
1-10000
CT Ratio Measurement Accuracy
0.5%
PT Ratio Measurement Range
1-10000
PT Ratio Measurement Accuracy
0.1%
Dimensions
380 X 240 X 180 mm
Weight
≤8 Kg
Transport Package
Wooden Box with Foam Inside
Specification
VS-2088A: PT AND CT ANALYZER (VARIABLE FREQUENCY)
Trademark
WESHINE
Origin
China Hebei
HS Code
9027100090
Production Capacity
500 Pieces/Per Month

Product Description


 

Product Description

The need for a comprehensive current transformer testing regime is evident when the alternative is considered: a catastrophically damaging current transformer fault. A fault leading to an open secondary could cause the primary current to overwhelm the insulation, causing the winding to short circuit. WESHINE's range of current transformer test equipment allows you to construct an in depth test and maintenance programme to prevent problems before they occur.

A routine series of diagnostics and testing for your current transformer should include CT saturation testing to identify the knee point against IEEE or IEC standards, CT ratio tests to identify that the voltage ratio is within expected parameters and current transformer resistance testing for both the transformer windings and CT insulation resistance testing.

Saturation testing for a current transformer identifies the rated knee point against IEEE or IEC standards, the point at which the transformer is no longer able to output current in proportion to its specified ratio.

Ratio tests under normal load are achieved by comparing voltage applied to the secondary winding against the resulting voltage produced on the primary winding. Current transformer resistance tests inject test voltage to measure the DC current and calculate the resistance with allowance for temperature. 


FEATURES:
* Variable frequency 
* 0 ~ 220 Vrms, 5 Arms, peak: 20 A 
* Current output up to 150A 
* Performs Secondary Burden tests
Upgraded on the basis of
VS-2800
* Variable frequency effective avoid the iron core resonance causes overvoltage.
* Less than 16 lb (8Kg), smallest and lightest unit on the market.
* Especially suitable for the test of Transient Current Transformer.

 
 
PRODUCT INFORMATION
Product Name
PT and CT Analyzer (variable frequency)
Output
0 ~ 220 Vrmas, 5 Arms
Output Current
0 ~ 150 A
CT grouped testing
* Demagnetization, Knee Points, Ratios, Saturation Curves, Winding Resistances, Polarities and Phase Deviation...
VT testing
* Demagnetization, Ratios, Winding Resistance, Polarity and Phase Deviation...
Weight
≤ 8 kg
Certificates
CE; EMC; LVD; ISO; IEC;
Dimensions
380mm*180mm*240mm
Model Number
VS-2800A

Frenquency CT PT Tester Transformer Characteristic Parameters Analyzer

Recommend Products

Frenquency CT PT Tester Transformer Characteristic Parameters AnalyzerFrenquency CT PT Tester Transformer Characteristic Parameters Analyzer

 

Feedback

Frenquency CT PT Tester Transformer Characteristic Parameters Analyzer

Company Profile

Frenquency CT PT Tester Transformer Characteristic Parameters AnalyzerFrenquency CT PT Tester Transformer Characteristic Parameters Analyzer


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More