Electric Line Cable Pipe Locator System Underground Fault Positioning

Weshine Electric Manufacturing Co., Ltd.
  • Audited Supplier
  • 5 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Comprehensive Testing Modes: Supports Direct Connection, Clamp Coupling, and Radiation modes for versatile fault detection.
  • High Precision Pinpointing: Acoustic techniques reduce error margin to 0.1% for exact fault location.
  • Wide Frequency Output: Generates frequencies from 640Hz to 197kHz for various cable types.
  • 24/7 Online Support: Round-the-clock technical assistance and free replacement parts available.
  • Full Customization Options: Offers customization from samples, designs, and flexible minor adjustments.
  • Multiple Cable Compatibility: Tests network, HDMI, audio, coaxial, digital, and high voltage cables.
  • ISO Certified Manufacturing: Factory holds ISO9001, ISO45001, and ISO14001 certifications for quality assurance.
  • Fast Lead Time: Peak and off-peak season delivery completed within 15 working days.

Product Images of Electric Line Cable Pipe Locator System Underground Fault Positioning

Electric Line Cable Pipe Locator System Underground Fault Positioning pictures & photos
Electric Line Cable Pipe Locator System Underground Fault Positioning
Electric Line Cable Pipe Locator System Underground Fault Positioning pictures & photos
Electric Line Cable Pipe Locator System Underground Fault Positioning
Electric Line Cable Pipe Locator System Underground Fault Positioning pictures & photos
Electric Line Cable Pipe Locator System Underground Fault Positioning
Electric Line Cable Pipe Locator System Underground Fault Positioning pictures & photos
Electric Line Cable Pipe Locator System Underground Fault Positioning
Electric Line Cable Pipe Locator System Underground Fault Positioning pictures & photos
Electric Line Cable Pipe Locator System Underground Fault Positioning
Electric Line Cable Pipe Locator System Underground Fault Positioning pictures & photos
Electric Line Cable Pipe Locator System Underground Fault Positioning
  • Electric Line Cable Pipe Locator System Underground Fault Positioning
    Electric Line Cable Pipe Locator System Underground Fault Positioning
  • Electric Line Cable Pipe Locator System Underground Fault Positioning
    Electric Line Cable Pipe Locator System Underground Fault Positioning
  • Electric Line Cable Pipe Locator System Underground Fault Positioning
    Electric Line Cable Pipe Locator System Underground Fault Positioning
  • Electric Line Cable Pipe Locator System Underground Fault Positioning
    Electric Line Cable Pipe Locator System Underground Fault Positioning
  • Electric Line Cable Pipe Locator System Underground Fault Positioning
    Electric Line Cable Pipe Locator System Underground Fault Positioning
  • Electric Line Cable Pipe Locator System Underground Fault Positioning
    Electric Line Cable Pipe Locator System Underground Fault Positioning

Find Similar Products

Product Description

 
Product Description

Cable fault location is required anywhere where the fault cannot be seen, this is a multi-step process that must be performed as safely and as quickly as possible because customers will be without power. Step 1 - Cable Isolation & Safety Procedures: A cable fault is nearly always a permanent fault. This means that the cable in question will be in a condition where the protection devices at one or both ends of the cable will have tripped, leaving the cable isolated but NOT earthed (grounded). The first task is for the Authorised Person for the site to make the cable safe by isolating and then earthing (grounding) one or both ends preferably. Only after the appropriate procedures have been carried out can any testing personnel be allowed to approach the cable and prepare for testing. Step 2 - Cable Identification: Where multiple cables exist, cable identification testing will identify the correct cable to work on. Clear identification before a cable is cut is intrinsic to safe maintenance work. Any mistakes here can be fatal, and may cause much longer outages for the connected customers Step 3 - Cable tracing: When an underground cable is first laid it rarely runs in a straight line, but rather meanders in depth and direction. Cable tracing is done to determine that the route of the cable is following the expected path. Step 4 - Fault identification: The first major procedure is to determine the phase on which the fault has occurred, and if it is of low or high resistance. This test determines the correct technique and equipment to diagnose the fault. Typically, if the fault is found to be below 100 Ohms, a low voltage pulse (e.g., 40 V) from a TDR (time domain reflectometer) can be used. If the fault is a higher resistance (> 100 Ohm), a low voltage pulse will likely not see it. For these types of faults, an Impulse generator (shock discharge) will be necessary. Step 5 - Fault prelocation: A reliable and precise pre-location method is necessary to locate a cable fault quickly and efficiently. Good pre-location can determine the fault position to within a few percent of the cable length and will reduce pinpointing time to a few minutes. Remember: a). If it is a low resistance fault, pre-location was likely to be the only means necessary for location. b). For high resistance faults, ARM (arc reflection) or ICE (impulse current) techniques on an SWG (surge wave generator) should be used. Alternatively, the decay method with an HV DC tester (bridge), can be used for pre-location. Step 6 - Pinpointing: The aforementioned test methods will get the operator with 5% distance of the fault, acoustic pinpointing techniques must be employed to narrow the margin of error to 0.1%. In most cases, shock discharge generators are used for pinpointing in conjunction with acoustic methods. The discharge creates a loud noise, which is pinpointed precisely using an acoustic pinpointing device. This device evaluates the time difference between the acoustic signal (speed of sound) and the electromagnetic (nearly the speed of light) impulse of the shock discharge. When the shortest time difference is indicated, the exact fault location is revealed. Step 7 - Re-energisation of the cable: Once all testing and repairs are completed, the Safety/Testing Documentation is cancelled. the cable is then handed back to the appropriate operators to reinstate the cable and re-energise the loads on the newly repaired cable.

Detailed Photos

Electric Line Cable Pipe Locator System Underground Fault PositioningElectric Line Cable Pipe Locator System Underground Fault PositioningElectric Line Cable Pipe Locator System Underground Fault Positioning

Electric Line Cable Pipe Locator System Underground Fault PositioningElectric Line Cable Pipe Locator System Underground Fault Positioning
Electric Line Cable Pipe Locator System Underground Fault Positioning
Electric Line Cable Pipe Locator System Underground Fault PositioningElectric Line Cable Pipe Locator System Underground Fault PositioningElectric Line Cable Pipe Locator System Underground Fault Positioning

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR266694". Items marked "verified" are certified.

Watch Video
Watch Video
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Room 602, Building 3, Diangu Technology Center, 3088 Lekai North Street, Baoding, Hebei, China
verified Plant Area
3000 square meters
verified Number of Employees
36
verified Registered Capital
15,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Tianjin Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
2

Our Production Capability & Technical Expertise

verified Main Products
Transformer Tester, Insulating Oil Tester, Hipot Tester, Insulating Tester, Circuit Breaker Tester, Relay and Protection Tester, Sf6 Gas Tester, Partial Discharge Tester, Battery Tester, Power Quality
verified Production Lines
1
verified Production Machines
Wire Stripping Machine, Super Mute Terminal Machine, Assembly Production Line, Constant Temperature and Humidity Chamber
verified QA/QC inspectors
2 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
10 people
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2013-09-17
verified Export Year
13 Years
verified Main Markets
South America, Southeast Asia/ Mideast
verified Repeat Buyers Choice
50%~80%
verified Number of Foreign Trading Staff
2
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015, ISO45001:2018, ISO14001, Others
verified Product Certification
Others
verified Cooperated with Fortune 500
No

FAQ

What types of cables can this system test?
It supports Network, HDMI, Audio, Coaxial, Digital, and High Voltage Cable testers.
How precise is the fault pinpointing?
Acoustic pinpointing techniques narrow the margin of error to 0.1%.
Is the product customizable?
Yes, we offer full customization, minor customization, and options from samples or designs.
What is the warranty period?
The product comes with a 1-year warranty and 7*24 online service.
What are the available payment terms?
We accept LC, T/T, D/P, PayPal, Western Union, and small-amount payments.
What is the minimum order quantity?
The minimum order quantity is 1 set.
How long does it take to deliver?
Lead time is within 15 working days for both peak and off-peak seasons.
Does the device support different measuring methods?
Yes, it includes Direct Connection Mode, Clamp Coupling Mode, and Radiation Mode.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs