Product Highlights

  • Customizable Output Voltage: Output voltage can be customized within the range of 30kv to 90kv.
  • Precise Fault Pinpointing: Acoustic pinpointing reduces error margin to 0.1% for exact location.
  • Long Standby Time: Device supports continuous operation for approximately 6 hours.
  • Comprehensive Certifications: Equipped with CE, EMC, LVD, ISO certifications for safety and quality.
  • Flexible Customization: Supports full customization, minor customization, and design-based options.
  • Multiple Measuring Methods: Utilizes Low-Voltage Pulse and Flash Current methods for fault detection.
  • No Blind Spots: Measuring range covers 0 to 5m with no blind spots.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of Advanced Underground Cable Fault Locator and Testing Kit

Advanced Underground Cable Fault Locator and Testing Kit pictures & photos
Advanced Underground Cable Fault Locator and Testing Kit
Advanced Underground Cable Fault Locator and Testing Kit pictures & photos
Advanced Underground Cable Fault Locator and Testing Kit
Advanced Underground Cable Fault Locator and Testing Kit pictures & photos
Advanced Underground Cable Fault Locator and Testing Kit
Advanced Underground Cable Fault Locator and Testing Kit pictures & photos
Advanced Underground Cable Fault Locator and Testing Kit
Advanced Underground Cable Fault Locator and Testing Kit pictures & photos
Advanced Underground Cable Fault Locator and Testing Kit
  • Advanced Underground Cable Fault Locator and Testing Kit
    Advanced Underground Cable Fault Locator and Testing Kit
  • Advanced Underground Cable Fault Locator and Testing Kit
    Advanced Underground Cable Fault Locator and Testing Kit
  • Advanced Underground Cable Fault Locator and Testing Kit
    Advanced Underground Cable Fault Locator and Testing Kit
  • Advanced Underground Cable Fault Locator and Testing Kit
    Advanced Underground Cable Fault Locator and Testing Kit
  • Advanced Underground Cable Fault Locator and Testing Kit
    Advanced Underground Cable Fault Locator and Testing Kit

Find Similar Products

Product Description

Split-type Cable Fault Location System
 

Product Description

Cable fault location is required anywhere where the fault cannot be seen, this is a multi-step process that must be performed as safely and as quickly as possible because customers will be without power.

Step 1 - Cable Isolation & Safety Procedures: A cable fault is nearly always a permanent fault. This means that the cable in question will be in a condition where the protection devices at one or both ends of the cable will have tripped, leaving the cable isolated but NOT earthed (grounded). The first task is for the Authorised Person for the site to make the cable safe by isolating and then earthing (grounding) one or both ends preferably. Only after the appropriate procedures have been carried out can any testing personnel be allowed to approach the cable and prepare for testing.
Step 2 - Cable Identification: Where multiple cables exist, cable identification testing will identify the correct cable to work on. Clear identification before a cable is cut is intrinsic to safe maintenance work. Any mistakes here can be fatal, and may cause much longer outages for the connected customers
Step 3 - Cable tracing: When an underground cable is first laid it rarely runs in a straight line, but rather meanders in depth and direction. Cable tracing is done to determine that the route of the cable is following the expected path.
Step 4 - Fault identification: The first major procedure is to determine the phase on which the fault has occurred, and if it is of low or high resistance. This test determines the correct technique and equipment to diagnose the fault. Typically, if the fault is found to be below 100 Ohms, a low voltage pulse (e.g., 40 V) from a TDR (time domain reflectometer) can be used. If the fault is a higher resistance (> 100 Ohm), a low voltage pulse will likely not see it. For these types of faults, an Impulse generator (shock discharge) will be necessary.
Step 5 - Fault prelocation: A reliable and precise pre-location method is necessary to locate a cable fault quickly and efficiently. Good pre-location can determine the fault position to within a few percent of the cable length and will reduce pinpointing time to a few minutes. Remember: a). If it is a low resistance fault, pre-location was likely to be the only means necessary for location. b). For high resistance faults, ARM (arc reflection) or ICE (impulse current) techniques on an SWG (surge wave generator) should be used. Alternatively, the decay method with an HV DC tester (bridge), can be used for pre-location.
Step 6 - Pinpointing: The aforementioned test methods will get the operator with 5% distance of the fault, acoustic pinpointing techniques must be employed to narrow the margin of error to 0.1%. In most cases, shock discharge generators are used for pinpointing in conjunction with acoustic methods. The discharge creates a loud noise, which is pinpointed precisely using an acoustic pinpointing device. This device evaluates the time difference between the acoustic signal (speed of sound) and the electromagnetic (nearly the speed of light) impulse of the shock discharge. When the shortest time difference is indicated, the exact fault location is revealed.
Step 7 - Re-energisation of the cable: Once all testing and repairs are completed, the Safety/Testing Documentation is cancelled. the cable is then handed back to the appropriate operators to reinstate the cable and re-energise the loads on the newly repaired cable.

For further information on Weshine's Service Solutions, contact our 24/7 online sales representative on Made in China or you may 
>>
Click Here(for PC) or Click "Send Inquiry" at the bottom (for APP) to get quotes from Weshine.
 

Detailed Photos


Advanced Underground Cable Fault Locator and Testing KitAdvanced Underground Cable Fault Locator and Testing KitAdvanced Underground Cable Fault Locator and Testing KitAdvanced Underground Cable Fault Locator and Testing KitAdvanced Underground Cable Fault Locator and Testing KitAdvanced Underground Cable Fault Locator and Testing Kit

Company Profile

 



Advanced Underground Cable Fault Locator and Testing KitAdvanced Underground Cable Fault Locator and Testing Kit

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR266694". Items marked "verified" are certified.

Watch Video
Watch Video
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Room 602, Building 3, Diangu Technology Center, 3088 Lekai North Street, Baoding, Hebei, China
verified Plant Area
3000 square meters
verified Number of Employees
36
verified Registered Capital
15,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Tianjin Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
2

Our Production Capability & Technical Expertise

verified Main Products
Transformer Tester, Insulating Oil Tester, Hipot Tester, Insulating Tester, Circuit Breaker Tester, Relay and Protection Tester, Sf6 Gas Tester, Partial Discharge Tester, Battery Tester, Power Quality
verified Production Lines
1
verified Production Machines
Wire Stripping Machine, Super Mute Terminal Machine, Assembly Production Line, Constant Temperature and Humidity Chamber
verified QA/QC inspectors
2 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
10 people
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2013-09-17
verified Export Year
13 Years
verified Main Markets
South America, Southeast Asia/ Mideast
verified Repeat Buyers Choice
50%~80%
verified Number of Foreign Trading Staff
2
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015, ISO45001:2018, ISO14001, Others
verified Product Certification
Others
verified Cooperated with Fortune 500
No

FAQ

What is the warranty period for this equipment?
The product comes with a 1-year warranty.
What are the available customization options?
We offer full customization, minor customization, customization from samples, and customization from designs.
What is the minimum order quantity?
The minimum order quantity is 1 piece.
How long is the average lead time?
The average lead time is one month for both peak and off-season periods.
What payment terms are accepted?
We accept LC, T/T, D/P, PayPal, Western Union, and small-amount payments.
What is the output voltage range?
The output voltage range is 30kv to 90kv.
What certifications does the product have?
The product is certified with CE, EMC, LVD, and ISO.
What is the standby time of the device?
The device can be used continuously for about 6 hours.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs