Secured Trading Service

VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection

Weshine Electric Manufacturing Co., Ltd.
  • Audited Supplier
  • 5 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Comprehensive After-Sales Support: 7*24 online service with free replacement for defective units.
  • 1-Year Warranty Coverage: Covers mechanical defects and functional failures for one year.
  • Full Customization Options: Offers customization from samples, designs, minor adjustments, and full customization.
  • Multiple Test Modes: Supports Direct Connection, Clamp Coupling, and Radiation modes.
  • High Voltage Cable Testing: Capable of testing high voltage cables with precision fault location.
  • CE and IEC Certification: Product meets international safety and quality standards.
  • ISO9001:2015 Certified: Manufacturing process certified for quality management.
  • OEM and ODM Services: Available for custom branding and design modifications.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection

VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection pictures & photos
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection pictures & photos
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection pictures & photos
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection pictures & photos
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection pictures & photos
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection pictures & photos
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
  • VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
    VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
  • VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
    VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
  • VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
    VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
  • VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
    VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
  • VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
    VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
  • VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
    VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection

Find Similar Products

Product Description

 
Product Description

Cable fault location is required anywhere where the fault cannot be seen, this is a multi-step process that must be performed as safely and as quickly as possible because customers will be without power. Step 1 - Cable Isolation & Safety Procedures: A cable fault is nearly always a permanent fault. This means that the cable in question will be in a condition where the protection devices at one or both ends of the cable will have tripped, leaving the cable isolated but NOT earthed (grounded). The first task is for the Authorised Person for the site to make the cable safe by isolating and then earthing (grounding) one or both ends preferably. Only after the appropriate procedures have been carried out can any testing personnel be allowed to approach the cable and prepare for testing. Step 2 - Cable Identification: Where multiple cables exist, cable identification testing will identify the correct cable to work on. Clear identification before a cable is cut is intrinsic to safe maintenance work. Any mistakes here can be fatal, and may cause much longer outages for the connected customers Step 3 - Cable tracing: When an underground cable is first laid it rarely runs in a straight line, but rather meanders in depth and direction. Cable tracing is done to determine that the route of the cable is following the expected path. Step 4 - Fault identification: The first major procedure is to determine the phase on which the fault has occurred, and if it is of low or high resistance. This test determines the correct technique and equipment to diagnose the fault. Typically, if the fault is found to be below 100 Ohms, a low voltage pulse (e.g., 40 V) from a TDR (time domain reflectometer) can be used. If the fault is a higher resistance (> 100 Ohm), a low voltage pulse will likely not see it. For these types of faults, an Impulse generator (shock discharge) will be necessary. Step 5 - Fault prelocation: A reliable and precise pre-location method is necessary to locate a cable fault quickly and efficiently. Good pre-location can determine the fault position to within a few percent of the cable length and will reduce pinpointing time to a few minutes. Remember: a). If it is a low resistance fault, pre-location was likely to be the only means necessary for location. b). For high resistance faults, ARM (arc reflection) or ICE (impulse current) techniques on an SWG (surge wave generator) should be used. Alternatively, the decay method with an HV DC tester (bridge), can be used for pre-location. Step 6 - Pinpointing: The aforementioned test methods will get the operator with 5% distance of the fault, acoustic pinpointing techniques must be employed to narrow the margin of error to 0.1%. In most cases, shock discharge generators are used for pinpointing in conjunction with acoustic methods. The discharge creates a loud noise, which is pinpointed precisely using an acoustic pinpointing device. This device evaluates the time difference between the acoustic signal (speed of sound) and the electromagnetic (nearly the speed of light) impulse of the shock discharge. When the shortest time difference is indicated, the exact fault location is revealed. Step 7 - Re-energisation of the cable: Once all testing and repairs are completed, the Safety/Testing Documentation is cancelled. the cable is then handed back to the appropriate operators to reinstate the cable and re-energise the loads on the newly repaired cable.

Detailed Photos

VS-2088A Cable Pipe Line Locator Device Clamp Coupling ConnectionVS-2088A Cable Pipe Line Locator Device Clamp Coupling ConnectionVS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection

VS-2088A Cable Pipe Line Locator Device Clamp Coupling ConnectionVS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
VS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection
VS-2088A Cable Pipe Line Locator Device Clamp Coupling ConnectionVS-2088A Cable Pipe Line Locator Device Clamp Coupling ConnectionVS-2088A Cable Pipe Line Locator Device Clamp Coupling Connection

 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR266694". Items marked "verified" are certified.

Watch Video
Watch Video
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.
Weshine Electric Manufacturing Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Room 602, Building 3, Diangu Technology Center, 3088 Lekai North Street, Baoding, Hebei, China
verified Plant Area
3000 square meters
verified Number of Employees
36
verified Registered Capital
15,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Tianjin Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
2

Our Production Capability & Technical Expertise

verified Main Products
Transformer Tester, Insulating Oil Tester, Hipot Tester, Insulating Tester, Circuit Breaker Tester, Relay and Protection Tester, Sf6 Gas Tester, Partial Discharge Tester, Battery Tester, Power Quality
verified Production Lines
1
verified Production Machines
Wire Stripping Machine, Super Mute Terminal Machine, Assembly Production Line, Constant Temperature and Humidity Chamber
verified QA/QC inspectors
2 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
10 people
verified Traceability of Raw Materials
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2013-09-17
verified Export Year
13 Years
verified Main Markets
South America, Southeast Asia/ Mideast
verified Repeat Buyers Choice
50%~80%
verified Number of Foreign Trading Staff
2
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015, ISO45001:2018, ISO14001, Others
verified Product Certification
Others
verified Cooperated with Fortune 500
No

FAQ

What is the warranty period for this device?
We provide a 1-year warranty covering mechanical defects and functional failures.
Is the product customizable?
Yes, we offer full customization options including customization from samples, designs, minor adjustments, and full customization.
What after-sales support is available?
We provide 7*24 online service and will change new units if defects occur.
What are the available test modes?
The device supports Direct Connection Mode, Clamp Coupling Mode, and Radiation Mode.
What is the minimum order quantity?
The minimum order quantity is 1 piece.
What payment methods do you accept?
We accept LC, T/T, D/P, PayPal, Western Union, and small-amount payments.
What is the lead time for production?
The average lead time is one month for both peak and off-peak seasons.
Is the product certified?
Yes, the product holds CE and IEC certifications.

Send your message to this supplier