• Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester
  • Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester
  • Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester
  • Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester
  • Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester
  • Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester

Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester

After-sales Service: 7*24 Online Service
Warranty: 1 Year
Accuracy Grade: 0.02
Display: Digital
Weight: 3 kg
Product Name: Earth Resistance and Soil Resistivity Tester
Samples:
US$ 690/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Feedback
  • Company Profile
Overview

Basic Info.

Model NO.
VS-3004
Typical Application
Measurement of earth resistance, soil resistivity,
Testing Method
Four-point method (Wenner method)
Accuracy
0.0001 μΩ
Test Range of Earth Resistance
0 to 200 kΩ
Test Range of Soil Resistivity
0.000 to 9999 kΩ·m
Test Range of Earth Voltage
AC 0.001 to 600 V (50Hz/60Hz)
Dimension
320 x 275 x 145 mm
Certificates
CE; EMC; LVD; ISO; IEC;
Transport Package
Wooden Box with Foam Inside
Specification
VS-3004: Earth Tester
Trademark
Weshine
Origin
Hebei, China
HS Code
9030332000
Production Capacity
2000 Pieces

Product Description

 

Product Description

The Earth faults are hazardous and hence need proper earthing to prevent fault current from entering into anybody or metallic object. The purpose of earthing is to minimize the effect of transient voltage that occurred due to a strike of lightning.

What are the methods of measuring earth resistance?
There are different earth resistance measurement methods used depending on the type of neutral system, the type of installation (residential, industrial, urban environment, rural environment, the possibility of cutting off the power supply. Four variables affect the earth resistance of a grounding system which includes:

1. The composition of the soil
2. The moisture content of the soil
3. The temperature of the soil
4. The depth of the electrode


The resistance of the earth electrode depends upon the resistivity of the soil in which the electrode is inserted. Therefore, it is crucial to measure the resistivity during the design of any earthing installations.

Earth resistance is the resistance of the ground electrode measured to perform a resistance check. With additional measurements like the voltage, the test electrode moved 10% of the original voltage electrode to the earth system, separating it from the initial position and 10% closer than its original position. When both of them agree with the measurement within the required level of accuracy, the test stakes are placed in a correct position, and the resistance can be obtained by averaging all three results.

Before starting any earth resistance measurements, the maximum value for correct earthing needs to be measured. There are six basic test methods to measure the earth resistance:

1. Four-point method (Wenner method)
2. Three terminal methods (falloff potential method/ 68.1% method)
3. Two-point method (dead earth method)
4. Clamp-on test method
5.  Slope method
6.  Star delta method


Based on the methods mentioned above,
Weshine have developed a Earth Tester Series (VS-3000 series), which combines the new lightning protection grounding resistance detection standard, specially for on-site measurement of earth resistance, soil resistivity, grounding voltage, AC voltage.

 

PRODUCT INFORMATION
Product Name
Digital Earth Resistance Tester
Typical Application
Measurement of earth resistance, soil resistivity, grounding voltage, AC voltage.
Testing Method
Four-point method (Wenner method)


Test Range
Earth Resistance
0 to 200 kΩ
Soil Resistivity
0.000 to 9999 kΩ·m
Earth Voltage
AC 0.001 to 600 V(50Hz/60Hz)
 
Resolution
Earth Resistance
0.001 Ω
Soil Resistivity
0.01 Ωm
Earth Voltage
0.001 V
 
 

Accuracy

Earth Resistance
1.0.000 to 10.00 kΩ: ±2%rdg±5dgt
2.10.0 to 100.0 kΩ: ±3%rdg±5dgt
3.100.0 to 200.0 kΩ: ±3.5%rdg±5dgt
Soil Resistivity
ρ=2πaR (a:1 m~100m);π=3.14)
Earth Voltage
±2%rdg±5dgt(50Hz/60Hz)
Weight
3 kg
Dimension
320 x 275 x 145 mm
Model Number
VS-3004
Certificates
CE; EMC; LVD; ISO; IEC;



Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance TesterDigital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance TesterDigital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance TesterDigital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance TesterDigital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance TesterDigital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester

Feedback

Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester

Company Profile

Digital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance TesterDigital Automatic Four-point Method Wenner Method Grounding Soil Resistivity and Earth Resistance Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now