• OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
  • OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
  • OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
  • OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
  • OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
  • OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables

OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables

After-sales Service: 24/7 Online Service
Warranty: 1 Year
Display Type: Analogue and Digital
Certification: CE
Customized: Customized
Product Name: OHV DAC Test System M30
Samples:
US$ 188000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • PD CUSTOMISED SOLUTIONS
  • Product Description
  • Recommend Products
  • Feedback
  • Company Profile
Overview

Basic Info.

Model NO.
OHV M30
DAC Output Voltage
60 kV (peak) / 42,4 kV (RMS)
DAC Frequency Range
20 Hz to 1000 Hz (acc. IEC 60060-3)
Test object capacitance
0.025 μF to 5 μF
PD range / resolution
5 pC to 100 nC / 1 pC
PD bandwidth
100 kHz to 500 kHz (acc. IEC 60270)
Joint locating in calibration mode
Integrated
PD locating
Wide-band, 100 kHz to 20 MHz Automatic adjustment
Dimensions
Diameter: ca. 620 mm Height: ca. 690 mm
Weight
75 kg
Transport Package
Wooden Box with Foam Inside
Specification
OHV M30: OHV DAC Test System M30
Trademark
Weshine
Origin
Hebei, China
HS Code
9031803100
Production Capacity
2000 Pieces

Product Description

PD CUSTOMISED SOLUTIONS

OWTS Cable PD Fault Locator Oscillating Wave Test System for Locating Partial Discharge Locations in Cables

* Poor installation
* Failures due to inappropriate laying
* Weak spots in cable accessories or
* Deterioration of cable insulation due to aging It allows much more than a simple go or no-go decision.

DAC testing is an advanced maintenance tool which supports asset management and grid operation as well.

* Sound withstand test method with test voltages representing operational stresses
* Sensitive PD measurement and location in complete cable systems (insulation and accessories)
* Assessment of cable aging status in comparison with other cables based on dissipation factor estimation.

On-site DAC voltage test in combination with non-destructive PD and loss factor measurements is unique and fundamental for reliable service of newly installed, repaired or service-aged cable systems.

The M30 series is an integrated partial discharge localization system, mainly used for partial discharge diagnosis of medium voltage cables. The M30 series is an integrated partial discharge localization system, mainly used for partial discharge diagnosis of medium voltage cables. The system tests a damped AC voltage (DAC) at frequencies from 20Hz to 1000Hz. The damping AC voltage generated by the system during the testing process can reach up to 30kV, and is combined with advanced system hardware and system software for diagnosis.
     mainly include:  
   - The latest transistor technology and laser control technology, such as high voltage transistor switches;
   - Electronic components, digital signal processing, such as high voltage transistor switches, high voltage sources;
- Digital signal processor and filter, data acquisition device A/D converter not less than 14Bit
   - All-in-one software, compatible with data from other similar manufacturers, and automatically export reports
The high-voltage unit can generate oscillating wave high-voltage signals, and the high-voltage generator can generate any value of high voltage of 0-30kV; the partial discharge test device for the distance positioning of partial discharge signals without blind spots, without blind spots, can perform partial discharge positioning for cables below 250m; 1 laptop computer for control; operating software (Chinese/German/English version); external safety control unit; analysis software (Chinese/German/English version); a 7.5-meter high-voltage connection line without partial discharge, and has an anti-drop safety design ; Power line, grounding line, check line, emergency stop line; PD under the highest voltage of the system is less than 1pC.
Unlimited installation of PD analysis software, which can be installed and analyzed on any computer, compatible with data analysis of various similar manufacturers, and has built-in TDR calibration test function, including ultra-low frequency VLF function, double-ended measurement and analysis function, can choose the analysis phase interval, test report One-click automatic generation, after the test is completed and the test report is automatically generated.

For further information on Weshine's Service Solutions, contact our 24/7 online sales representative on Made in China or you may >>
Click Here(for PC) or Click "Send Inquiry" at the bottom (for APP) to get quotes from Weshine.

OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
 

Product Description

OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
The intuitive and user friendly diagnostic suite helps to improve measurement and data handling. It combines the control of the test system with data handling and basic evaluation options.
The PD-Mapping allows you to identify spots of increased PD activity depending on test voltage.
OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
 
OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
The software has a lot of functions, for example the ability to automatize testing procedures, which help to make the test even more comfortable.
 
Enhanced time domain reflectometry (TDR) options, including keyboard short-cut controls to increase evaluation speed.
OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables
 

 

Recommend Products

OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables

Feedback

OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables

Company Profile

OHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage CablesOHV M30 Cable Oscillating Wave Partial Discharge Test System Damped AC Diagnosis Partial Discharge of Medium Voltage Cables

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now