• Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
  • Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

After-sales Service: 24/7 Online Service
Warranty: 1 Year
Display Type: Analogue and Digital
Certification: CE
Customized: Customized
Product Name: Transformer Area Identifier
Samples:
US$ 2890/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Recommend Products
  • Feedback
  • Company Profile
Overview

Basic Info.

Model NO.
VS-X705
Transformer Area Identifier
Realize the users in the same transformer area.
Communication Distance
3 km
Current Test Distance
≥ 5 km
Communication Mode
Low frequency zero crossing communication technolo
Jaw Diameter
7mm(5A), 50mm(100A/500A)
Identification Accuracy
100 %
Certificates
CE; EMC; LVD; ISO; IEC;
Three Identification Modes
Meet the needs of different sites
Feature
Portable/Handheld
Transport Package
Wooden Box with Foam Inside
Specification
VS-X705: Transformer Area Identifier
Trademark
Weshine
Origin
Hebei, China
HS Code
903033900
Production Capacity
2000 Pieces

Product Description

 

Product Description

During the operation of power grid companies for many years, due to various technical reasons, non-standard management or power and responsibility adjustment, the end-user meter files do not conform to the actual situation, and it is difficult to determine the location of the ground cable power users. Further, the disordered accounts cause that the analysis of line loss rate, distribution network fault location, emergency repair work list issuance and three-phase imbalance analysis and some other advanced applications cannot be effectively carried out. Seriously affected the process of building smart grid by Power Grid Corp.
 
For this reason, Weshine invented the Transformer Area Identifier which based on the high correlation of voltage data of the same electrical energy acquisition equipment, the voltage data of users are clustered to realize the users in the same transformer area. Examples show that the proposed transformer area recognition method can accurately and effectively identify the user transformer area and phase information and reduce the labor and hardware costs. It is of great significance to guide the operation, maintenance, emergency repair, technical renovation and planning of low-voltage distribution network.
 
PRODUCT INFORMATION
Product Name
Transformer Area Identifier
Typical Application
The voltage data of users are clustered to realize the users in the same transformer area.
Communication Distance
3 km
Current Test Distance
≥ 5 km
Communication Mode
Low frequency zero crossing communication technology
 
 
SIGNIFICANCE 
of 
TRANSFORMER 
AREA 
IDENTIFIER
(1) Accurately check the subordination relationship of the substation area line of the system, facilitate the adjustment of the substation area power load, and ensure the safety of power use. 
(2) Reduce the line loss rate of the substation area to make it meet the national standard. 
(3) Ensure that the archive is consistent with the actual station area, and improve the success rate of carrier meter reading, so that it will not fluctuate significantly for a long time. 
(4) It is easy to adjust the carrier routing node and solve the difficult problem of carrier meter reading by clarifying the line ownership and phase relationship in the station area. 
(5) During the transformation of urban and rural power grids, the corresponding relationship between electric energy meter, user and station area line shall be checked accurately to improve the efficiency and accuracy of meter replacement.
Jaw Diameter
7mm(5A), 50mm(100A/500A)
Identification Accuracy
100 %
Model Number
VS-X705
Certificates
CE; EMC; LVD; ISO; IEC;


Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer AreaTransformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
TYPICAL APPLICATION
(1) Multi-mode identification method: Three identification modes are optional, which can meet the needs of different sites.
(2) Branch identification: It can determine the electricity branch (switch) to which a user belongs, and the function is more practical.
(3) Phase identification: It can determine which phase a user belongs to in the station area, and the display is intuitive.
(4) Line voltage drop display: The outlet voltage of the host side (low voltage side of the transformer) and the 220V access port voltage of the user under test can be displayed on the same screen, and the voltage drop amplitude on the user's power supply line can be obtained to provide first-hand data for rationally deploying balanced loads. .
(5) Large storage capacity: at least 800 groups of tested user information can be stored, and can be consulted at any time. Data export function: The host has a USB data interface that can export the information of all the tested users, which is convenient for the sorting and statistics of the information in the station area.
(6) The plastic shell of the main unit is made of high-molecular impact-resistant engineering plastic portable outer box, which has good mechanical properties and certain waterproof function, beautiful appearance, light weight, and is convenient for on-site use.
(7) Both the host and the extension use a large-screen dot-matrix liquid crystal display, all displayed in simplified Chinese, and the operation is intuitive and easy to understand at a glance.
(8) The whole machine is equipped with complete accessories, which can meet various needs of different sites.
(9) The multi-mode identification method can accurately determine the distribution transformer area or the branch (switch) of the electrical circuit to which the user belongs. The identification accuracy reaches 100%, the signal strength is high, and the transmission distance is long.
(10) The number of hosts and extensions is flexible. Since the numbers of the host and extensions can be set at will through the keyboard, user identification in the power supply area of multiple distribution transformers (switches) under complex conditions can be realized.
(11) Both the main unit and the extension have a memory function. After setting the working mode once, there is no need to reset the working mode when the machine is turned on again.
(12) It has the function of displaying the port voltage, the user terminal voltage and the line voltage drop on the same screen, which is convenient for comparing the voltage drop and provides a reference for the rational allocation of balanced loads.
(13) Both the main unit and the extension have the function of power supply misconnection protection and alarm prompt function. When the 220V power supply is misconnected to 380V, the circuit will automatically judge and cut off the internal circuit, and at the same time, it will issue a sound and light alarm prompt.
(14) There are two options for the working power supply of the host, the test voltage line is powered by electricity and the external DC power supply module is installed.
(15) The main circuit of the host adopts a high-speed processor with strong data processing capability and powerful storage capability, which can store at least 800 sets of test data, which can be consulted at any time, and the stored data results can be exported through the USB data interface.
  

Recommend Products

Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area
 
VS-X710
POWER QUALITY ANALYZER
* 0.05 to 6 A(up to 1500 A), 10 to 450 V
* 3 voltage channels/3 current channels
 
MEASURED PARAMETERS:
 
* Power parameters (KW, KVAR, KVA, DPF, TPF)
* Energy parameters (KWH, KVARH, KVAH)
* Voltage/current unbalance
* RMS voltage/current
* Total demand distortion
* Harmonics
* Harmonic ripples
* Total harmonic distortion
* Flicker
* Phase angles
* Phase angle deviation
VS-X710
POWER QUALITY ANALYZER
* 1280*800 Touch LCD screen
* 0 to 25 A(up to 2000 A), 0 to 900 V
* 4 voltage channels/4 current channels
 
MEASURED PARAMETERS:
 
* Power parameters (KW, KVAR, KVA, DPF, TPF)
* Energy parameters (KWH, KVARH, KVAH)
* Voltage/current unbalance
* RMS voltage/current
* Total demand distortion
* Harmonics
* Harmonic ripples
* Total harmonic distortion
* Flicker
* Phase angles
* Phase angle deviation
Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area


 

Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

Feedback

Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

Company Profile

Transformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer AreaTransformer Area Identifier for Clustered Voltage Data of Users and Realize the Users in the Same Transformer Area

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now